Diagnostics & fault analysis error messages – Lenze E94ARNE Regenerative power supply User Manual
Page 207
EDS94ARNExxxx EN 2.3 - 06/2014
L
207
9400 regenerative power supply module | Parameter setting
Diagnostics & fault analysis
Error messages
6815748
MXI1: Module changed during operation
Warning locked
-
6815765
MXI1: Module has been changed
Information or warning locked if
the hardware type has changed
as well.
-
6815754
MXI1: Module is defect or missing
Fault
-
9175053
MXI1: Module is missing or incompatible
Fault
-
9175055
MXI1: PROFIBUS module is missing or incompatible
Fault
-
6815760
MXI1: Wrong module
System fault
-
9175064
MXI2: CAN module is missing or incompatible
Fault
-
9175058
MXI2: Ethernet module is missing or incompatible
Fault
-
9175062
MXI2: ICM module is missing or incompatible
Fault
-
6815749
MXI2: Module changed during operation
Warning locked
-
6815766
MXI2: Module has been changed
Information or warning locked if
the hardware type has changed
as well.
-
6815755
MXI2: Module is defect or missing
System fault
-
9175054
MXI2: Module is missing or incompatible
Fault
-
9175056
MXI2: PROFIBUS module is missing or incompatible
Fault
-
6815761
MXI2: Wrong module
System fault
-
6946819
New applications loaded
Information
-
9502722
No heartbeat signal detected
System fault
-
9437194
No parameter for module in MXI1
Fault
9437195
No parameter for module in MXI2
Fault
9437184
Parameter set faulty
Fault
-
9437187
Parameter set loaded
Information
-
9437189
Parameter set restored
Fault
-
9437186
Parameter set saved
Information
-
9437193
Parameter set: type of standard device has been changed
Information
-
9437191
Parameter set: Version conflict
Fault
-
6946837
PDO mapping (MXI1): Faulty configuration
Fault
-
6946838
PDO mapping (MXI2): Faulty configuration
Fault
-
8192001
PLC configuration invalid
Fault
-
8060983
PLC configuration invalid
Fault
-
7667718
PLC configuration invalid
Fault
-
6946834
Pointer access in impermissible memory area
Fault
-
9502736
Position value faulty
Fault
-
8060947
Power control: Task overflow
System fault
-
6815759
Power section incompatible
System fault
-
6815745
Power section is defect
System fault
-
6815753
Power section is defect
System fault
-
8060994
Power section is defect
System fault
-
6815764
Power stage has been changed
Information or warning locked if
the hardware type has changed
as well.
-
9175050
Project not available
Fault
-
9175049
Project not loaded
Fault
-
7471104
Read error service register
Fault
-
8061000
Relay malfunction (inside of filter)
Fault
-
9175051
Required licence missing
Fault
-
6815768
Safety module has been changed
Information or warning locked if
the hardware type has changed
as well.
-
6815751
Safety module has been removed
System fault
-
6815747
Safety module is defect or missing
System fault
-
Error number
Error message
Response
Adjustable in
hex
dec
(Lenze setting)