9400 regenerative power supply module | Parameter setting

Device interface

Device commands

44

L

EDS94ARNExxxx EN 2.3 - 06/2014

4.1.6

Save start parameters

Parameter changes in the regenerative power supply module carried out via the

»Engineer« or keypad will get lost after mains switching of the regenerative power supply

module, or after loading another application, unless the settings have been explicitly

saved.
The

C00002

= "11: Save start parameters" device command can be used to save the current

parameter settings of the active application with mains failure protection in the memory

module of the regenerative power supply module.

[4-5]

"Save start parameters" function

Tip!
The left function key of the keypad can be used to execute this device command if

the  function is currently assigned to this key.

* In this example application 1 is the active application

PS

9400

RAM

Firmware

Application 1*

PS

Application 3

PS

Application 2

PS

Memory module MM

PS

Application 1*

Note!

The storing process can take a few seconds. Before switching off the supply

voltage after this device command has been executed, check via the status

display in

C00003

that the device command has been executed successfully!