I-1010 – Lenze E94ARNE Regenerative power supply User Manual
Page 151
EDS94ARNExxxx EN 2.3 - 06/2014
L
151
9400 regenerative power supply module | Parameter setting
"CAN on board" system bus
Implemented CANopen objects
I-1010
Saving the parameters with mains failure protection.
Corresponds to the device command
= "11: Save start parameters".
This command serves to store the current parameter settings of the active application
with mains failure protection in the memory module of the regenerative power supply
module.
Reading subindex 1
[6-3]
Assignment of the data telegram (read access)
Writing to subindex 1
In addition to index and subindex, the telegram data must include the signature “save“
(ASCII characters; ISO 8859) to start the parameter saving (see table).
A response according to the specification DS301 V4.02 occurs when a wrong identifier
is used for writing.
[6-4]
Assignment of the data telegram (write access)
Index:
I-1010
Name:
Store parameters
Subindex
Default setting
Setting range (min. value | unit | max. value)
Access
Data type
0: Highest subindex supported
1
- (read access only)
ro
U32
1: Save all parameters
-
0
4294967295 rw
U32
Subindex
Meaning
Reading
Writing
0
Max. number of supported subindexes: 1 -
(A write attempt results in the error
message 0x06010002.)
1
Reading of the storing functionality of all
parameters.
Saving the parameters with mains
failure protection.
8th byte
7th byte
6th byte
5th byte
Data 4
Data 3
Data 2
Data 1
Bit 31 ... bit 2
Bit 1
Bit 0
0
0/1
0/1
Bit
Meaning
Bit 0
0 Saving of parameters on command not possible.
1 Saving of parameters on command possible (Lenze).
Bit 1
0 Automatic saving of parameters not possible (Lenze).
1 Automatic saving of parameters possible.
8th byte
7th byte
6th byte
5th byte
Data 4
Data 3
Data 2
Data 1
"e" = 0x65
"v" = 0x76
"a" = 0x61
"s" = 0x73