C00064 | device utilisation (ixt), C00065 | ext. 24-v voltage, C00068 | capacitor temperature – Lenze E94ARNE Regenerative power supply User Manual
Page 278: C00069 | cpu temperature, C00070 | dc bus voltage ctrl. gain, C00071 | dc bus voltage ctrl. reset time, C00075 | current controller gain, Ic filter nameplate (enp), C00070, C00071
9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00064
278
L
EDS94ARNExxxx EN 2.3 - 06/2014
C00064
C00065
C00068
C00069
C00070
C00071
C00075
Parameter | Name:
C00064 | Device utilisation (Ixt)
Data type: UNSIGNED_32
Index: 24511
d
= 5FBF
h
Device utilisation during the last 180 seconds
• C00064 > 100 % activates error (OC5).
• Error reset only possible if C00064 < 95 %.
Display range
(min. value | unit | max. value)
0
%
250
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00065 | Ext. 24-V voltage
Data type: INTEGER_32
Index: 24510
d
= 5FBE
h
Display range
(min. value | unit | max. value)
0.0
V
1000.0
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00068 | Capacitor temperature
Data type: INTEGER_32
Index: 24507
d
= 5FBB
h
Display range
(min. value | unit | max. value)
-200
°C
200
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00069 | CPU temperature
Data type: INTEGER_32
Index: 24506
d
= 5FBA
h
Display range
(min. value | unit | max. value)
-200
°C
200
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00070 | DC bus voltage ctrl. gain
Data type: UNSIGNED_32
Index: 24505
d
= 5FB9
h
Note: This parameter is only effective in closed-loop operation (in preparation).
Setting range
(min. value | unit | max. value)
Lenze setting
0.00000
Nm/rpm
20000.00000 0.00400 Nm/rpm
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100000
Parameter | Name:
C00071 | DC bus voltage ctrl. reset time
Data type: UNSIGNED_32
Index: 24504
d
= 5FB8
h
Note: This parameter is only effective in closed-loop operation (in preparation).
Setting range
(min. value | unit | max. value)
Lenze setting
1.0
ms
6000.0 50.0 ms
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00075 | Current controller gain
Data type: UNSIGNED_32
Index: 24500
d
= 5FB4
h
Note: This parameter is only effective in closed-loop operation (in preparation).
Setting range
(min. value | unit | max. value)
Lenze setting
0.00
V/A
750.00 30.00 V/A
Read access Write access CINH PLC STOP No transfer
Scaling factor: 100