C00143 | sampled peak power, C00144 | time stamp of sampled max. power, C00145 | energy out – Lenze E94ARNE Regenerative power supply User Manual
Page 283: Displayed in, C00143/1, Splay value, C00144/1, C00143/2, C00144/2, C00143/3

EDS94ARNExxxx EN 2.3 - 06/2014
L
283
9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00143
C00143
C00144
C00145
Parameter | Name:
C00143 | Sampled peak power
Data type: UNSIGNED_32
Index: 24432
d
= 5F70
h
From software version V2.0 onwards
display the elapsed-hour meter reading at which the respective peak power has been reached.
Display range
(min. value | unit | max. value)
0.0
kW
10000.0
Subcodes
Information
C00143/1
Max. DC-power mot.
C00143/2
Max. DC-power reg. (+ br. chop.)
C00143/3
Max. line power reg.
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00144 | Time stamp of sampled max. power
Data type: UNSIGNED_32
Index: 24431
d
= 5F6F
h
From software version V2.0 onwards
Displays the elapsed-hour meter reading at which the respective peak power displayed in
has been
reached.
Display range
(min. value | unit | max. value)
0
s
4294967295
Subcodes
Information
C00144/1
Time stamp max. DC-power mot.
C00144/2
Time stamp max. DC-power reg.
C00144/3
Time stamp max. line power
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00145 | Energy out
Data type: INTEGER_32
Index: 24430
d
= 5F6E
h
From software version V2.0 onwards
Display of transmitted and regenerated energy
Display range
(min. value | unit | max. value)
-2147483.647
kWh
2147483.647
Subcodes
Information
C00145/1
Output energy (DC)
C00145/2
Regenerated energy (AC)
Read access Write access CINH PLC STOP No transfer
Scaling factor: 1000