9400 regenerative power supply module | Parameter setting

Oscilloscope

Operation

7.4.5

Adjusting the representation

After the variable values have been recorded and the online data record has been

transferred to the PC, the data record is visualised in the oscillograph. If required, the

representation can now be adjusted by using the zoom or the automatic scaling function.

Zoom function

Go to the Oscilloscope toolbar and click the icon to activate the zoom function.

Automatic scaling function
Use the automatic scaling function to automatically scale and reposition the

representation of selectable signal characteristics in the oscillograph and reset it to the

offset "0".

Zoom function

Procedure

Zoom selection

Hold down the left mouse button and draw the oscillograph section to be

zoomed:

• The selection is shown with a frame.

• When the left mouse button is released, the selection is zoomed in the

oscillograph.

Horizontal/vertical

shift of selection

Hold down the left and right mouse button and move the mouse pointer on the

horizontal scale to the left or right or on the vertical scale to the top or bottom

to shift the selection accordingly.

• With a three-button mouse, you can use the mouse button in the middle.

Horizontal stretching

Hold down the left mouse button and move the mouse pointer on the horizontal

scale to the left to stretch the shown selection from the right edge.

• Moving the mouse pointer in opposite direction continuously reduces the

stretching.

Hold down the right mouse button and move the mouse pointer on the

horizontal scale to the right to stretch the shown selection from the left edge.

• Moving the mouse pointer in opposite direction continuously reduces the

stretching.

Vertical stretching

Hold down the left mouse button and move the mouse pointer on the vertical

scale to the bottom to stretch the shown selection from the top.

• Moving the mouse pointer in opposite direction continuously reduces the

stretching.

Hold down the right mouse button and move the mouse pointer on the vertical

scale to the top to stretch the shown selection from the bottom.

• Moving the mouse pointer in opposite direction continuously reduces the

stretching.

Return to original

representation

Click the right mouse button in the oscillograph to return step by step to the

original representation.