C00126 | cpu temp. warning threshold, C00129 | brake resistor value, C00130 | rated power of brake resistor – Lenze E94ARNE Regenerative power supply User Manual
Page 281: C00131 | therm. capacity brake resistor, C00132 | activation brake chopper, C00129, C00130, C00131, C00132, Is to be used

EDS94ARNExxxx EN 2.3 - 06/2014
L
281
9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00126
C00126
C00129
C00130
C00131
C00132
Parameter | Name:
C00126 | CPU temp. warning threshold
Data type: UNSIGNED_32
Index: 24449
d
= 5F81
h
Temperature threshold for advance warning of CPU temperature on the control card
• The response to be initiate when the threshold is reached can be selected in
.
Setting range
(min. value | unit | max. value)
Lenze setting
0
°C
85 70 °C
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00129 | Brake resistor value
Data type: INTEGER_32
Index: 24446
d
= 5F7E
h
Required for monitoring of the brake resistor temperature.
Parameterising the brake chopper/brake resistor
Setting range
(min. value | unit | max. value)
Lenze setting
0.0
Ohm
500.0 180.0 Ohm
Read access Write access CINH PLC STOP No transfer
Scaling factor: 10
Parameter | Name:
C00130 | Rated power of brake resistor
Data type: INTEGER_32
Index: 24445
d
= 5F7D
h
Required for monitoring of the brake resistor temperature.
Parameterising the brake chopper/brake resistor
Setting range
(min. value | unit | max. value)
Lenze setting
0
W
800000 5600 W
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00131 | Therm. capacity brake resistor
Data type: INTEGER_32
Index: 24444
d
= 5F7C
h
Required for monitoring of the brake resistor temperature.
Parameterising the brake chopper/brake resistor
Setting range
(min. value | unit | max. value)
Lenze setting
0
kWs
100000 485 kWs
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00132 | Activation brake chopper
Data type: UNSIGNED_8
Index: 24443
d
= 5F7B
h
From software version V2.0 onwards
Setting the brake chopper activation
Selection list
(Lenze setting printed in bold)
Information
0 Overvoltage
1 Overvoltage + overcurrent
2 Overvolt. + overcur. + util.
Read access Write access CINH PLC STOP No transfer