Parameter reference table of attributes – Lenze E94ARNE Regenerative power supply User Manual
Page 342
9400 regenerative power supply module | Parameter setting
Parameter reference
Table of attributes
342
L
EDS94ARNExxxx EN 2.3 - 06/2014
Maximum effective power
24518
5FC6
E
1
INTEGER_32
10
Heatsink temperature
24514
5FC2
E
1
INTEGER_32
1
Temperature inside the controller
24513
5FC1
E
1
INTEGER_32
1
Filter temperature
24512
5FC0
E
1
INTEGER_32
1
Device utilisation (Ixt)
24511
5FBF
E
1
UNSIGNED_32
1
Ext. 24-V voltage
24510
5FBE
E
1
INTEGER_32
10
Capacitor temperature
24507
5FBB
E
1
INTEGER_32
1
CPU temperature
24506
5FBA
E
1
INTEGER_32
1
DC bus voltage ctrl. gain
24505
5FB9
E
1
UNSIGNED_32
100000
DC bus voltage ctrl. reset time
24504
5FB8
E
1
UNSIGNED_32
10
Current controller gain
24500
5FB4
E
1
UNSIGNED_32
100
Current contr. reset time
24499
5FB3
E
1
UNSIGNED_32
100
Filter resistance
24491
5FAB
E
1
UNSIGNED_32
10000
Filter inductance
24490
5FAA
E
1
UNSIGNED_32
1000
Firmware version
24476
5F9C
E
1
VISIBLE_STRING
1
Dig. input x: Terminal polarity
24461
5F8D
A
8
UNSIGNED_8
1
Dig. output x: Terminal polarity
24457
5F89
A
4
UNSIGNED_8
1
Filter temp. warning threshold
24454
5F86
E
1
UNSIGNED_32
1
Heatsink temp. warn. threshold
24453
5F85
E
1
UNSIGNED_32
1
Warning threshold device util.
24452
5F84
E
1
UNSIGNED_32
1
CPU temp. warning threshold
24449
5F81
E
1
UNSIGNED_32
1
Brake resistor value
24446
5F7E
E
1
INTEGER_32
10
Rated power of brake resistor
24445
5F7D
E
1
INTEGER_32
1
Therm. capacity brake resistor
24444
5F7C
E
1
INTEGER_32
1
Activation brake chopper
24443
5F7B
E
1
UNSIGNED_8
1
Ref.: Brake chopper utilisation
24442
5F7A
E
1
UNSIGNED_8
1
Minimum brake resistance
24441
5F79
E
1
INTEGER_32
10
Brake transistor utilisation
24438
5F76
E
1
INTEGER_32
1
Brake resistor utilisation
24437
5F75
E
1
INTEGER_32
1
Autom. restart after mains ON
24433
5F71
E
1
UNSIGNED_32
1
Sampled peak power
24432
5F70
A
3
UNSIGNED_32
10
Time stamp of sampled max. power
24431
5F6F
A
3
UNSIGNED_32
1
Energy out
24430
5F6E
A
2
INTEGER_32
1000
Status word device control 1
24425
5F69
E
1
BITFIELD_16
1
Status word device control 2
24420
5F64
E
1
BITFIELD_16
1
Status/Control word ECTRL
24419
5F63
A
2
UNSIGNED_32
1
Controller inhibit by (source)
24417
5F61
E
1
BITFIELD_16
1
Masked error number
24413
5F5D
A
3
UNSIGNED_32
1
Error description
24409
5F59
E
1
VISIBLE_STRING
1
Error number
24407
5F57
E
1
UNSIGNED_32
1
Logbook - event filter
24406
5F56
E
1
BITFIELD_32
1
Mains voltage
24402
5F52
E
1
UNSIGNED_8
1
Elapsed hour meter
24397
5F4D
E
1
UNSIGNED_32
1
Power-on time meter
24396
5F4C
E
1
UNSIGNED_32
1
Service code
24395
5F4B
E
1
VISIBLE_STRING
Red. brake chopper threshold
24394
5F4A
E
1
UNSIGNED_32
1
Device state
24392
5F48
E
1
UNSIGNED_32
1
ENP: Identified filter type
24389
5F45
E
1
VISIBLE_STRING
1
ENP: Identified serial number
24388
5F44
E
1
VISIBLE_STRING
1
ENP: Status
24387
5F43
E
1
UNSIGNED_8
1
Device name
24376
5F38
E
1
VISIBLE_STRING
1
Code
Name
Index
Data
Access
dec
hex
DS
DA
DT
Factor
R
W
CINH