0x008c000c, 0x008c0011, 0x008c000d – Lenze E94ARNE Regenerative power supply User Manual
Page 238: 0x008c000f, 0x008c000e, 0x008c0010, Diagnostics & fault analysis error messages

9400 regenerative power supply module | Parameter setting
Diagnostics & fault analysis
Error messages
238
L
EDS94ARNExxxx EN 2.3 - 06/2014
Application and device are incompatible [0x008c000c]
MXI1: Module is missing or incompatible [0x008c000d]
MXI2: Module is missing or incompatible [0x008c000e]
MXI1: PROFIBUS module is missing or incompatible [0x008c000f]
MXI2: PROFIBUS module is missing or incompatible [0x008c0010]
MXI1: Ethernet module is missing or incompatible [0x008c0011]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Application is incompatible with the regenerative power
supply module.
• Download an application that is compatible with the
regenerative power supply module via the Engineer.
• Switch off regenerative power supply module and
insert another memory module that is suitable for the
application.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The extension module in module slot MXI1 is
incompatible with the application.
Use extension module supported by the application.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The extension module in module slot MXI2 is
incompatible with the application.
Use extension module supported by the application.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The communication module E94AYCPM (PROFIBUS) in
module slot MXI1 is incompatible with the application.
Use communication module supported by the
application.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The communication module E94AYCPM (PROFIBUS) in
module slot MXI2 is incompatible with the application.
Use communication module supported by the
application.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The communication module E94AYCEN (Ethernet) in
module slot MXI1 is incompatible with the application.
Use communication module supported by the
application.