4 logbook, Logbook – Lenze E94ARNE Regenerative power supply User Manual
Page 192

9400 regenerative power supply module | Parameter setting
Diagnostics & fault analysis
Logbook
192
L
EDS94ARNExxxx EN 2.3 - 06/2014
8.4
Logbook
The integrated logbook function of the regenerative power supply module chronologically
logs important events within the system and thus plays an important role for
troubleshooting or diagnostics of the regenerative power supply module.
Events that can be logged
The following events can be recorded in the logbook:
Error messages generated by the application
Controller enable
Starting/stopping the application
Loading/saving parameter sets, loading the Lenze setting
Transferring an application or firmware into the regenerative power supply module
Switching the regenerative power supply module on/off
Formatting the file system
Tip!
Use a parameterisable filter to exclude certain events from being recorded in the
Information saved
For each event the following information is saved in the logbook:
Type of response (e.g. trouble, warning or information) to the event
Event
Value of power-on time meter
Date/time (for memory module with real-time clock)
Module that triggered the event (A = application; S = system).
Memory depth
The possible number of logbook entries depends on the memory module used:
MM1xx, MM2xx: 7 entries
MM3xx, MM4xx: 439 entries