9400 regenerative power supply module | Parameter setting
Internal interfaces
LS_SyncInput - status information for the sync telegram
264
L
EDS94ARNExxxx EN 2.3 - 06/2014
9.7
LS_SyncInput - status information for the sync telegram
The LS_SyncInput system block provides status information concerning the sync telegram
received via the system bus in the function block editor.
Outputs
Synchronisation of PDOs via sync telegram
Identifier
Data type
Value/meaning
SYNC_wSyncCycleTime
WORD
Sync cycle time in [μs]
• The sync cycle time, which can be set in
, is the time interval with which
the internal phase-locking loop (PLL) expects the sync signals. It must be set
appropriately with regard to the cycle of the synchronisation source selected in
SYNC_wSource
WORD
Synchronisation source selected in
0 OFF
1 CAN on-board
2 CAN module
4 Module in MXI1
5 Module in MXI2
6 Digital input 1
7 Digital input 2
8 Digital input 3
9 Digital input 4
10 Digital input 5
11 Digital input 6
12 Digital input 7
13 Digital input 8
SYNC_nSyncDeviation
INT
Deviation of the synchronisation signal in [increments]
• ±16000 increments ≡ ±1 ms
SYNC_bSyncInsideWindow
BOOL
Status signal "Synchronisation signal within time slot"
TRUE The last synchronisation signal was within the time slot
parameterised around the expected value via
.
SYNC_bSyncSignalReceived
BOOL
Status signal "Synchronisation signal received"
TRUE Synchronisation signal has been received.
SYNC_nSyncDeviation
SYNC_wSyncCycleTime
SYNC_wSource
SYNC_bSyncInsideWindow
SYNC_bSyncSignalReceived
LS_SyncInput
SYNC
SYNC