beautypg.com

C00604 | resp. to device overload > c00123, C00610 | resp. to failure heatsink fan, C00611 | resp. to failure integral fan – Lenze E94ARNE Regenerative power supply User Manual

Page 319: C00612 | resp. to can node guarding error, C00604, Occu, C00612/1, Go to, C00610, C00611

background image

EDS94ARNExxxx EN 2.3 - 06/2014

L

319

9400 regenerative power supply module | Parameter setting

Parameter reference

Parameter list | C00604

C00604

C00610

C00611

C00612

Parameter | Name:

C00604 | Resp. to device overload > C00123

Data type: UNSIGNED_32

Index: 23971

d

= 5DA3

h

Response if adjustable "I x t" warning threshold (

C00123

) is reached.

Selection list

(Lenze setting printed in bold)

1 Fault
5 Warning
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00610 | Resp. to failure heatsink fan

Data type: UNSIGNED_32

Index: 23965

d

= 5D9D

h

Response if fan speed of heatsink fan is too low.
Selection list

(Lenze setting printed in bold)

1 Fault
5 Warning
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00611 | Resp. to failure integral fan

Data type: UNSIGNED_32

Index: 23964

d

= 5D9C

h

Response if fan speed of interior fan is too low.
Selection list

(Lenze setting printed in bold)

1 Fault
5 Warning
0 No response

Read access  Write access  CINH  PLC STOP  No transfer

Parameter | Name:

C00612 | Resp. to CAN node guarding error

Data type: UNSIGNED_8

Index: 23963

d

= 5D9B

h

Response of master if the corresponding node guarding response is not received.

"CAN on board" system bus: node guarding protocol

Selection list

(Lenze setting printed in bold)

1 Fault
2 Trouble
4 Warning locked
5 Warning
6 Information
0 No response

Subcodes

Lenze setting

Information

C00612/1

0: No response

Response to non-received telegram for monitoring entry

1 ... 32

C00612/...
C00612/32

Read access  Write access  CINH  PLC STOP  No transfer