C00188 | enp: status, C00199 | device name, C00200 | firmware product type – Lenze E94ARNE Regenerative power supply User Manual
Page 289: C00201 | firmware - compiling date, C00203 | hw product types, C00200, C00201, C00203

EDS94ARNExxxx EN 2.3 - 06/2014
L
289
9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00188
C00188
C00199
C00200
C00201
C00203
Parameter | Name:
C00188 | ENP: Status
Data type: UNSIGNED_8
Index: 24387
d
= 5F43
h
Selection list
(display only)
0 No ENP found
1 ENP data loaded
2 Known ENP found
3 ENP found but not read
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00199 | Device name
Data type: VISIBLE_STRING
Index: 24376
d
= 5F38
h
Device name to be defined by the user (e.g. "cross cutter" or "lifting axis 1") with max. 128 characters
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00200 | Firmware product type
Data type: VISIBLE_STRING
Index: 24375
d
= 5F37
h
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00201 | Firmware - compiling date
Data type: VISIBLE_STRING
Index: 24374
d
= 5F36
h
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00203 | HW product types
Data type: VISIBLE_STRING
Index: 24372
d
= 5F34
h
Subcodes
Information
C00203/1
Type: Control card
C00203/2
Type: Power section
C00203/3
Type: Module in MXI1
C00203/4
Type: Module in MXI2
C00203/5
Type: Memory module
C00203/6
Type: Safety module
C00203/7
Type: Standard device
C00203/8
Type: Complete device
C00203/9
Type: ENP
Read access Write access CINH PLC STOP No transfer