C01206 | counter: mains switching, C01208 | counter: heatsink overtemp, C01209 | counter: housing overtemp – Lenze E94ARNE Regenerative power supply User Manual
Page 328: C01211 | service code, C01212 | counter: power section overload, C01213 | service code, C01214 | internal clock

9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C01206
328
L
EDS94ARNExxxx EN 2.3 - 06/2014
C01206
C01208
C01209
C01211
C01212
C01213
C01214
Parameter | Name:
C01206 | Counter: Mains switching
Data type: UNSIGNED_16
Index: 23369
d
= 5B49
h
Display range
(min. value | unit | max. value)
0
65535
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C01208 | Counter: Heatsink overtemp.
Data type: UNSIGNED_16
Index: 23367
d
= 5B47
h
Display range
(min. value | unit | max. value)
0
65535
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C01209 | Counter: Housing overtemp.
Data type: UNSIGNED_16
Index: 23366
d
= 5B46
h
Display range
(min. value | unit | max. value)
0
65535
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C01211 | Service code
Data type: UNSIGNED_32
Index: 23364
d
= 5B44
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C01212 | Counter: Power section overload
Data type: UNSIGNED_16
Index: 23363
d
= 5B43
h
Display range
(min. value | unit | max. value)
0
65535
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C01213 | Service code
Data type: UNSIGNED_32
Index: 23362
d
= 5B42
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C01214 | Internal clock
Data type: VISIBLE_STRING
Index: 23361
d
= 5B41
h
Display of the device's system time in the format "dd/mm/yyyy hh:mm:ss"
• Time and date are set via
.
If the MM440 memory module with real-time clock is plugged into the regenerative power supply module, the
internal clock is adjusted to the real-time clock every time the power is switched on and every 24 hours at 0:00
o'clock.
• The daily adjustment is executed on a low-priority level. This is why it may take some seconds until the adjusted
time is displayed.
• During the adjustment process, status information of the real-time clock is also queried and error messages are
entered into the logbook if necessary.
Note:
If a memory module without real-time clock is plugged into the regenerative power supply module, the internal
clock is initialised with "01.01.1970 00:00:00" every time the power is switched on.
Read access Write access CINH PLC STOP No transfer