Parameter | Name:
C00214 | Required safety module
Data type: UNSIGNED_8
Index: 24361
d
= 5F29
h
Note: The regenerative power supply module does not support any safety engineering.
• The SM0 safety module (without safety engineering) must be inserted into the regenerative power supply
module.
• If a different safety module is detected, an error (trouble) will be activated. The error can only be reset by mains
switching.
Selection list
(Lenze setting printed in bold)
1 SM0
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00217 | Service code
Data type: UNSIGNED_32
Index: 24358
d
= 5F26
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00218 | Application: ID number
Data type: UNSIGNED_32
Index: 24357
d
= 5F25
h
Display range
(min. value | unit | max. value)
0
0
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00219 | Service code
Data type: UNSIGNED_32
Index: 24356
d
= 5F24
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00225 | Service code
Data type: UNSIGNED_32
Index: 24350
d
= 5F1E
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00227 | Behaviour due to change of parameterset
Data type: UNSIGNED_32
Index: 24348
d
= 5F1C
h
From software version V2.0 onwards
If you select "1" in the corresponding subcode, you can exclude a module inserted in slot MXI1 / MXI2 from the
parameter set changeover via the device command "Activate parameter set n".
• This significantly speeds up the parameter set changeover, especially for active modules.
• An exclusion from the parameter set changeover is useful, for instance, if different parameter sets are used (e.g.
for different tools on the machine), but the parameters for the module always remain the same (e.g.
communication parameters).
Selection list
(Lenze setting printed in bold)
0 Included
1 Excluded
Subcodes
Lenze setting
Information
C00227/1
0: Included
Change of parameter set: MXI1
C00227/2
0: Included
Change of parameter set: MXI2
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00308 | Service code
Data type: UNSIGNED_16
Index: 24267
d
= 5ECB
h
This code is used internally by the device and must not be overwritten by the user!