Diagnostics & fault analysis error messages – Lenze E94ARNE Regenerative power supply User Manual
Page 206

9400 regenerative power supply module | Parameter setting
Diagnostics & fault analysis
Error messages
206
L
EDS94ARNExxxx EN 2.3 - 06/2014
6946822
IdleTask: Overflow
Fault
-
7929856
Incorrect device command transfer
System fault
-
6815762
Incorrect memory module
System fault
-
6815763
Incorrect safety module
System fault
-
7798801
Inside the device: Fan is defect
Fault
7798795
Inside the device: Thermal detector is defect
Fault
8060980
Internal communication error (DMA)
System fault
-
8060948
Internal communication error (host MCTRL)
System fault
-
8060982
Internal communication error (MCTRL host)
System fault
-
6881289
Internal error (event mechanism)
System fault
-
6881290
Internal error (event mechanism)
System fault
-
6881293
Internal error (file system lifetime)
Warning
-
6881282
Internal error (LDS instance data)
System fault
-
6881283
Internal error (LDS tasks)
System fault
-
6881281
Internal error (memory area - logbook)
System fault
-
6881286
Internal error (message memory)
System fault
-
6881287
Internal error (message queue)
System fault
-
6881288
Internal error (name data base)
System fault
-
6881291
Internal error (semaphores)
System fault
-
6881292
Internal error (semaphores)
System fault
-
6881284
Internal error (storage blocks)
System fault
-
6881285
Internal error (task queue)
System fault
-
9502724
Internal error: See C00180
System fault
-
9502725
Internal error: See C00180
System fault
-
9502726
Internal error: See C00180
System fault
-
9502728
Internal error: See C00180
Fault
-
9502729
Internal error: See C00180
Fault
-
9437185
Lenze setting loaded
Information
-
9437188
Loading of Lenze setting failed
Fault
-
6619136
Logbook: Overflow
Information
-
6619137
Logbook: Reset (read error)
Information
-
6619138
Logbook: Reset (version error)
Information
-
8061001
Mains not connected
Trouble
-
8060997
Mains voltage 10% too high
Warning
-
8060995
Mains voltage 10% too low
Warning
-
8060998
Mains voltage 15% too high
Fault
-
8060996
Mains voltage 15% too low
Fault
-
9502721
Mains voltage is switched off
Information
-
9502720
Mains voltage is switched on
Information
-
6815767
Memory module has been changed
Information or warning locked if
the hardware type has changed
as well.
-
6815750
Memory module has been removed
System fault
-
6815746
Memory module is defect or missing
Fault
-
6815756
Memory module is defect or missing
System fault
-
6619139
Memory module is missing
Information
-
6815772
Memory module: Faulty file system
Fault
-
8126464
Memory module: File system has been formatted
Information
-
8126465
Memory module: File system has been restored
Information
-
9175063
MXI1: CAN module is missing or incompatible
Fault
-
9175057
MXI1: Ethernet module is missing or incompatible
Fault
-
9175061
MXI1: ICM module is missing or incompatible
Fault
-
Error number
Error message
Response
Adjustable in
hex
dec
(Lenze setting)