3 short overview (a-z), Short overview (a-z), Table in the chapter – Lenze E94ARNE Regenerative power supply User Manual
Page 203: Cont, Diagnostics & fault analysis error messages
EDS94ARNExxxx EN 2.3 - 06/2014
L
203
9400 regenerative power supply module | Parameter setting
Diagnostics & fault analysis
Error messages
8.6.3
Short overview (A-Z)
The following table contains all error messages of the regenerative power supply module
in alphabetical order with the preset error response and - if available – the parameter for
setting the error response.
Tip!
If you click the cross-reference in the first column, you get to the detailed
description of the corresponding error message in the chapter "
".
Error number
Error message
Response
Adjustable in
hex
dec
(Lenze setting)
8192000
Analog input 1: Master current < 4 mA
Fault
9175052
Application and device are incompatible
Fault
-
6946835
Application has started
Information
-
6946830
Application has stopped
Information
-
6946836
Application has stopped
Information
-
6946820
ApplicationTask: Overflow
Fault
9502738
Block function in wrong MEC task
Fault
-
8060992
Brake chopper: Ixt > C00570
Warning
8060993
Brake resistance: I2t > C00572
Warning
8060957
Brake resistance: I²xt overload
Information
-
8060956
Brake transistor: Ixt overload
No response
8060961
Brake transistor: Overcurrent
Fault
-
10551304
CAN module (MXI1) PDO manager: Faulty configuration
Warning locked
-
10551296
CAN module (MXI1) RPDO1: Telegram not received or faulty
No response
C13591/1
10551297
CAN module (MXI1) RPDO2: Telegram not received or faulty
No response
C13591/2
10551298
CAN module (MXI1) RPDO3: Telegram not received or faulty
No response
C13591/3
10551299
CAN module (MXI1) RPDO4: Telegram not received or faulty
No response
C13591/4
10551300
CAN module (MXI1) RPDO5: Telegram not received or faulty
No response
C13591/5
10551301
CAN module (MXI1) RPDO6: Telegram not received or faulty
No response
C13591/6
10551302
CAN module (MXI1) RPDO7: Telegram not received or faulty
No response
C13591/7
10551303
CAN module (MXI1) RPDO8: Telegram not received or faulty
No response
C13591/8
10682368
CAN module (MXI1) SDO client: Faulty configuration
Warning locked
-
10616832
CAN module (MXI1) SDO server: Faulty configuration
Warning locked
-
10289154
CAN module (MXI1): Basic configuration invalid
Warning locked
-
10289152
CAN module (MXI1): Bus off
Information
C13595
10420224
CAN module (MXI1): Faulty emergency configuration
Warning locked
-
10485792
CAN module (MXI1): Faulty NMT master configuration
Warning locked
-
10354721
CAN module (MXI1): Faulty NMT slave configuration
Warning locked
-
10354688
CAN module (MXI1): Heartbeat error index 1 ... 32
No response
C13613/1...32
10289153
CAN module (MXI1): Invalid node address 0
Warning
-
10354720
CAN module (MXI1): Lifeguarding error
No response
C13614
10485760
CAN module (MXI1): node guarding error 1 ... 32
No response
C13612/1...32
11534344
CAN module (MXI2) PDO manager: Faulty configuration
Warning locked
-
11534336
CAN module (MXI2) RPDO1: Telegram not received or faulty
No response
C14591/1
11534337
CAN module (MXI2) RPDO2: Telegram not received or faulty
No response
C14591/2
11534338
CAN module (MXI2) RPDO3: Telegram not received or faulty
No response
C14591/3
11534339
CAN module (MXI2) RPDO4: Telegram not received or faulty
No response
C14591/4
11534340
CAN module (MXI2) RPDO5: Telegram not received or faulty
No response
C14591/5