C00513 | service code, C00514 | service code, C00515 | service code – Lenze E94ARNE Regenerative power supply User Manual
Page 313: C00516 | service code, C00569 | resp. brake trans. ixt > c00570, C00570 | warning thres. brake transistor, C00569, C00570, Default setting: "warning")
EDS94ARNExxxx EN 2.3 - 06/2014
L
313
9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00513
C00513
C00514
C00515
C00516
C00569
C00570
Parameter | Name:
C00513 | Service code
Data type: VISIBLE_STRING
Index: 24062
d
= 5DFE
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00514 | Service code
Data type: UNSIGNED_32
Index: 24061
d
= 5DFD
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00515 | Service code
Data type: UNSIGNED_32
Index: 24060
d
= 5DFC
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00516 | Service code
Data type: UNSIGNED_32
Index: 24059
d
= 5DFB
h
This code is used internally by the device and must not be overwritten by the user!
Parameter | Name:
C00569 | Resp. brake trans. ixt > C00570
Data type: UNSIGNED_32
Index: 24006
d
= 5DC6
h
Response if adjustable warning threshold (
) of brake chopper monitoring is reached.
Parameterising the brake chopper/brake resistor
Selection list
(Lenze setting printed in bold)
1 Fault
2 Trouble
5 Warning
4 Warning locked
0 No response
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00570 | Warning thres. brake transistor
Data type: UNSIGNED_32
Index: 24005
d
= 5DC5
h
Warning threshold for brake chopper monitoring
• The response to be initiated when the threshold is reached can be selected in
Parameterising the brake chopper/brake resistor
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
100 90 %
Read access Write access CINH PLC STOP No transfer