Code refresh [0x00690000, Internal error (memory area - logbook) [0x00690001, Internal error (lds instance data) [0x00690002 – Lenze E94ARNE Regenerative power supply User Manual
Page 215: Internal error (lds tasks) [0x00690003, 0x00690000, 0x00680020, 0x00680021, 0x00690002, 0x00690003, 0x00690001
EDS94ARNExxxx EN 2.3 - 06/2014
L
215
9400 regenerative power supply module | Parameter setting
Diagnostics & fault analysis
Error messages
Combination of module in MXI1/device not possible [0x00680020]
Combination of module in MXI2/device not possible [0x00680021]
Code Refresh [0x00690000]
Internal error (memory area - logbook) [0x00690001]
Internal error (LDS instance data) [0x00690002]
Internal error (LDS tasks) [0x00690003]
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The extension module in module slot MXI1 is not
supported by the regenerative power supply module.
• Remove the extension module and switch the mains.
• Plug in supported extension module and switch the
mains.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The extension module in module slot MXI2 is not
supported by the regenerative power supply module.
• Remove the extension module and switch the mains.
• Plug in supported extension module and switch the
mains.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Serious device error or component failure.
Switch off regenerative power supply module, and then
switch it on again.
• Please contact Lenze if the problem occurs again.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Serious device error or component failure.
Switch off regenerative power supply module, and then
switch it on again.
• Please contact Lenze if the problem occurs again.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Serious device error or component failure.
Switch off regenerative power supply module, and then
switch it on again.
• Please contact Lenze if the problem occurs again.
Response (Lenze setting printed in bold)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Serious device error or component failure.
Switch off regenerative power supply module, and then
switch it on again.
• Please contact Lenze if the problem occurs again.