9400 regenerative power supply module | Parameter setting
"CAN on board" system bus
Parameter data transfer
Meaning of the error code
Error code
Explanation
0x0503 0000
Toggle bit not changed.
0x0504 0000
SDO protocol expired.
0x0504 0001
Invalid or unknown client/server command specifier.
0x0504 0002
Invalid block size (only block mode).
0x0504 0003
Invalid processing number (only block mode).
0x0504 0004
CRC error (only block mode).
0x0504 0005
Not sufficient memory.
0x0601 0000
Object access not supported.
0x0601 0001
Attempt to read a write-only object.
0x0601 0002
Attempt to write to a read-only object.
0x0602 0000
Object not listed in object directory.
0x0604 0041
Object not mapped to PDO.
0x0604 0042
Number and length of objects to be transferred longer than PDO length.
0x0604 0043
General parameter incompatibility.
0x0604 0047
General internal device incompatibility.
0x0606 0000
Access denied because of hardware error.
0x0607 0010
Unsuitable data type (unsuitable service parameter length).
0x0607 0012
Unsuitable data type (service parameter length exceeded).
0x0607 0013
Unsuitable data type (service parameter length not long enough).
0x0609 0011
Subindex does not exist.
0x0609 0030
Parameter value range exceeded.
0x0609 0031
Parameter values too high.
0x0609 0032
Parameter values too low.
0x0609 0036
Maximum value falls below minimum value.
0x0800 0000
General error.
0x0800 0020
Data cannot be transferred/stored for application.
0x0800 0021
Data cannot be transferred/stored for application due to local control.
0x0800 0022
Data cannot be transferred/stored for application due to current device state.
0x0800 0023
Dynamic generation of object directory failed or no object directory available (e.g. object
directory generated from file, generation not possible because of a file error).