C00322 | can tpdox tx mode, C00323 | can rpdox rx mode, C00324 | can tpdox delay time – Lenze E94ARNE Regenerative power supply User Manual
Page 296: C00325 | service code, C00322/1, C00323/1, C00324/1, C00323/2, C00323/3, C00323/4

9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00322
296
L
EDS94ARNExxxx EN 2.3 - 06/2014
C00322
C00323
C00324
C00325
Parameter | Name:
C00322 | CAN TPDOx Tx mode
Data type: UNSIGNED_8
Index: 24253
d
= 5EBD
h
TPDO transmission mode according to DS301 V4.02
• Types 0 (acyclic sync), 1-240 (cyclic sync), 254 (event-controlled manufacturer-specific), 255 (event-controlled
device-profile-specific) are supported.
• The basic PDO setting is "254" (event-controlled).
(see DS301 V4.02).
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Information
C00322/1
254
Transmission mode for TPDO1 ... TPDO4
C00322/...
C00322/4
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00323 | CAN RPDOx Rx mode
Data type: UNSIGNED_8
Index: 24252
d
= 5EBC
h
RPDO transmission mode according to DS301 V4.02
• Serves as monitoring setting for RPDOs in case of sync-controlled PDOs.
• Types 0 (acyclic sync), 1-240 (cyclic sync), 254 (event-controlled manufacturer-specific), 255 (event-controlled
device-profile-specific) are supported.
• The basic PDO setting is "254" (event-controlled).
(see DS301 V4.02).
Setting range
(min. value | unit | max. value)
0
255
Subcodes
Lenze setting
Information
C00323/1
254
Transmission mode for RPDO1 ... RPDO4
C00323/...
C00323/4
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00324 | CAN TPDOx delay time
Data type: UNSIGNED_16
Index: 24251
d
= 5EBB
h
TPDO inhibit time according to DS301 V4.02
• Minimum time between the sending of two identical TPDOs.
• The delay time is entered in 1/10 ms and automatically rounded to full milliseconds by the code.
(see DS301 V4.02).
Setting range
(min. value | unit | max. value)
0
1/10 ms
65535
Subcodes
Lenze setting
Information
C00324/1
0 1/10 ms
Delay time for TPDO1 ... TPDO4
C00324/...
C00324/4
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00325 | Service code
Data type: UNSIGNED_8
Index: 24250
d
= 5EBA
h
This code is used internally by the device and must not be overwritten by the user!