1 state "initialisation active, State "initialisation active – Lenze E94ARNE Regenerative power supply User Manual
Page 80
9400 regenerative power supply module | Parameter setting
Device interface
Device states
80
L
EDS94ARNExxxx EN 2.3 - 06/2014
Display parameters for diagnostic purposes
The current device state is displayed in
.
(status word 1) displays the current device state in a bit-coded manner via
bits 8 ... 11:
4.2.1
State "Initialisation active"
This is the device state of the regenerative power supply module directly after switching
on the supply voltage.
In this device state the operating system is initialised.
The application is not processed yet.
The monitoring mode is not active yet.
Communication is not possible yet.
The regenerative power supply module cannot be parameterised yet and no device
commands can be executed.
When the device initialisation is completed, the device state is automatically changed
to "Device is ready to switch on".
Bit 11
Bit 10
Bit 9
Bit 8
Meaning
0
0
0
0
0
0
0
1
State "Device is ready to switch on"
0
0
1
0
-
0
0
1
1
0
1
0
0
-
0
1
0
1
-
0
1
1
0
0
1
1
1
The regenerative power supply module is ready to switch on,
switched on, or operation is enabled and a warning is indicated.
1
0
0
0
1
0
0
1
-
1
0
1
0
-
1
0
1
1
-
1
1
0
0
1
1
0
1
-
1
1
1
0
-
1
1
1
1
-
LED DRIVE READY
LED DRIVE ERROR
OFF
OFF
10: Initialisation active