9400 regenerative power supply module | Parameter setting
Parameter reference
Parameter list | C00348
C00348
C00349
C00350
Parameter | Name:
C00348 | CAN status DIP switch
Data type: UNSIGNED_8
Index: 24227
d
= 5EA3
h
• "1" means that the CAN DIP switch has been identified after mains switching and a valid baud rate and node
address have been set.
• "0" means that no CAN DIP switch or no valid setting has been identified or the setting has been overwritten by
writing to code
or
.
Display range
(min. value | unit | max. value)
0
1
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00349 | CAN setting of DIP switch
Data type: UNSIGNED_8
Index: 24226
d
= 5EA2
h
Setting of the CAN DIP switch at last power-on
Display range
(min. value | unit | max. value)
0
255
Subcodes
Information
C00349/1
Node address
C00349/2
Baud rate:
0: 500 kbps
1: 250 kbps
2: 125 kbps
3: 50 kbps
4: 1 Mbps
5: 20 kbps
6: 10 kbps
14: 800 kbps
255: Automatic recognition
Read access Write access CINH PLC STOP No transfer
Parameter | Name:
C00350 | CAN node address
Data type: UNSIGNED_8
Index: 24225
d
= 5EA1
h
• A change of the node address only becomes effective after a CAN reset node.
• The basic server channel RX/TX is automatically coupled to the node address (
1).
• Overwriting the value deactivates a possibly existing hardware assignment of the node address.
Setting range
(min. value | unit | max. value)
Lenze setting
1
127 1
Read access Write access CINH PLC STOP No transfer