beautypg.com

I-1003 – Lenze E94ARNE Regenerative power supply User Manual

Page 148

background image

9400 regenerative power supply module | Parameter setting

"CAN on board" system bus

Implemented CANopen objects

148

L

EDS94ARNExxxx EN 2.3 - 06/2014

I-1003

Error history
This object indicates that an error has occurred in the module and in the standard device.

Index:

I-1003

Name:

Pre-defined error field

Subindex

Default setting

Setting range (min. value | unit | max. value)

Access

Data type

0: Number of errors

0

0

255 rw

U8

1 ... 10: Standard error field

-

0

4294967295 ro

U32

Subindex

Meaning

0

Number of saved error messages

1 ... 10

Display of the error list

The error messages (U32) consist of a 16-bit error code and a manufacturer-specific

information field comprising 16 bits.

Note!

The values in the "Standard error field" under subindexes 1 ... 10 will be deleted

if the subindex "Number of recorded errors" is overwritten with the value "0".

Emergency

error code

Cause

Entry in the error

register

(

I-1001

)

0x0000

One of several errors eliminated

0xXX

Elimination of one single error

(afterwards no more errors)

0x00

0x1000

Standard device is in the error state (error response "trouble",

"message", "warning", "fault", "quick stop by trouble" or "system

fault")

0x01

0x3100

Supply voltage of the standard device faulty or failed

0x01

0x8100

Communication error (warning)

0x11

0x8130

Life guard error or heartbeat error

0x11

0x8150

Collision of COB-IDs: An ID parameterised for reception is also used

for transmission.

0x11

0x8210

PDO length shorter than expected

0x11

0x8220

PDO length longer than expected

0x11

0x8700

Monitoring of sync telegram

0x11