Index
Conf
gur
ng the DX1000/DX2000
Trend nterval [/dv]
Select the time corresponding to 1 division of the time axis on the trend display from
below: You cannot specify a trend interval that is faster than the scan interval. See the
table under “Save Interval” below.
15s*, 30s, 1min, 2min, 5min, 10min, 15min, 20min, 30min, 1h, 2h, 4h, and 10h
* Can be set on the DX1002, DX1002N, DX1004, DX1004N, DX2004 and DX2008.
Save Interval (when recordng dsplay data)
Select the size of a record data file. The recorded data is divided by the file size
specified here. The available settings vary depending on the Trend interval setting.
Trend interval
Selectable range of
auto save interval
Trend interval
Selectable range of
auto save interval
Trend interval
Selectable range of
auto save interval
*1 Selectable on the DX1002, DX1002N, DX1004, DX1004N, DX2004, and DX2008 (release
number 3 or later).
*2 Selectable in fast sampling mode on the DX1006, DX1006N, DX1012, DX1012N, DX2010,
DX2020, DX2030, DX2040, and DX2048 (release number 3 or later).
5 s*
1
10 s*
1
15 s*
2
30 s
1 min
10 min to
10 min to
10 min to
10 min to
10 min to
12 hours
1 day
3 days
7 days
14 days
2 min
5 min
10 min
15 min
20 min
10 min to
10 min to
10 min to
10 min to
1 hour to
14 days
31 days
31 days
31 days
31 days
30 min
1 h
2 h
4 h
10 h
1 hour to
1 hour to
2 hours to
4 hours to 8 hours to
31 days
31 days
31 days
31 days
31 days
Crcular Tme Per revoluton [/rev]
Select the time of revolution from [20min]* to [4week].
* For release number 2 or earlier, this can only be specified on the DX2004 and DX2008.
For release number 3 and later, this can be specified during the fast sampling mode on the
DX2010, DX2020, DX2030, DX2040 and DX2048 in addition to DX2004 and DX2008.
Crcular Save Interval
Select the size of a record data file. The recorded data is divided by the file size
specified here. The available settings vary in the range of [10min] to [31day] depending
on the [Time Per revolution] setting.
Crcular Offset Tme
The time at the reference position on the circle can be offset in unit of an hour up to 23
hours. The available settings vary depending on the [Time Per revolution] setting.
Dsplay Update 2nd Interval
Enabled when [Trend Rate Switching] is turned [ON] under [Environment] - [Detail
Setting] in the [Basic Setting] tab. Select a rate from the list.
The selectable 2nd intervals are the same as those for Trend interval.
Drecton
Set the display direction of the trends to [Horizontal], [Vertical], [Wide], or [Split].
Trend Clear
Settngs
Descrpton
ON
Clears the displayed waveform when the memory sampling is started.
OFF
Does not clear the waveform when the memory sampling is started.
This is fixed at [ON] if you are using the multi batch function (/BT2 option; release
number 3 or later). You can set the multi batch function by setting [Batch operation qty]
under [Environment] - [Detail Setting] in the [Basic setting] tab.