Instruction Set Overview
5-20
5.3.3
Conditional Jumps
Conditional jumps support program branching relative to the program counter.
The possible jump range is from – 511 to +512 words relative to the program
counter state of the jump instruction. The 10-bit program-counter offset value
is treated as a signed 10-bit value that is doubled and added to the program
counter. None of the jump instructions affect the status bits.
The instruction code fetch and the program counter increment technique end
with the formula:
PC
new
= PC
old
+ 2 + PC
offset
×
2
Figure 5–9 shows the conditional-jump instruction format.
Figure 5–9. Conditional-Jump Instruction Format
C
10-Bit PC Offset
15
0
Opcode
8
7
14
13
12
11
10
9
6
5
4
3
2
1
Table 5–17 describes these conditional-jump instructions.
Table 5–17.Conditional-Jump Instructions
Mnemonic
S-Reg, D-Reg
Operation
JEQ/JZ
Label
Jump to label if zero bit is set
JNE/JNZ
Label
Jump to label if zero bit is reset
JC
Label
Jump to label if carry bit is set
JNC
Label
Jump to label if carry bit is reset
JN
Label
Jump to label if negative bit is set
JGE
Label
Jump to label if (N .XOR. V) = 0
JL
Label
Jump to label if (N .XOR. V) = 1
JMP
Label
Jump to label unconditionally