Timer_a, Chapter 10 – Texas Instruments MSP430x1xx User Manual
Page 141

10-1
Timer_A
Timer_A
This section describes the basic functions of the MSP430 general-purpose
16-bit Timer_A. All capture/compare blocks (CCR) are identical.
MSP430x11x, MSP430x11x1, and MSP430x13x have three CCRs
(Timer_A3) and MSP430x14x has five CCRs (Timer_A5) implemented.
Note:
Throughout this chapter, the word
count is used in the text. As used in these
instances, it refers to the literal act of counting. It means that the counter must
be in the process of counting for the action to take place. If a particular value
is directly written to the counter, then the associated action will not take place.
For example, the CCR0 interrupt flag is set when the timer
counts up to the
value in CCR0. The counter
must count from CCR0–1 to CCR0. If the CCR0
value were simply written directly to the timer with software, the interrupt flag
would
not be set, even though the values in the timer and the CCR0 registers
are the same.
Topic
Page
10.1 Introduction
10-2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10.2 Time Operation
10-4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10.3 Timer Modes
10-7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10.4 Capture/Compare Blocks
10-13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10.5 The Output Unit
10-19
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10.6 Timer_A Registers
10-24
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10.7 Timer_A UART
10-33
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chapter 10