beautypg.com

Clear summertime, Clear summertime -19 – Enterasys Networks Enterasys D2 D2G124-12P User Manual

Page 57

background image

clear summertime

D-Series CLI Reference 2-19

Defaults

If an offset is not specified, none will be applied.

Mode

Switch command, read‐write.

Example

This example shows how set daylight savings time to recur starting on the first Sunday of April at 
2 a.m. and ending the last Sunday of October at 2 a.m. with an offset time of one hour:

D2(su)->set summertime recurring first Sunday April 02:00 last Sunday October
02:00 60

clear summertime

Use this command to clear the daylight savings time configuration.

Syntax

clear summertime

Parameters

None.

Defaults

None.

Mode

Switch command, read‐write.

Example

This example shows how to clear the daylight savings time configuration:

D2(su)->clear summertime

start_day 

Specifies the day of the week to restart daylight savings time. 

start_hr_min

Specifies the time of day to restart daylight savings time. Format is 
hh:mm.

end_week

Specifies the week of the month to end daylight savings time. 

end_day

Specifies the day of the week to end daylight savings time.

end_hr_min

Specifies the time of day to end daylight savings time. Format is hh:mm.

offset_minutes

(Optional) Specifies the amount of time in minutes to offset daylight 
savings time from the non‐daylight savings time system setting. Valid 
values are 1 ‐ 1440.

This manual is related to the following products: