beautypg.com

Set newaddrtrap, Show snmp notify, Set newaddrtrap -30 show snmp notify -30 – Enterasys Networks Enterasys D2 D2G124-12P User Manual

Page 184

background image

set newaddrtrap

5-30 SNMP Configuration

set newaddrtrap

Use this command to enable or disable SNMP trap messaging, globally or on one or more ports, 
when new source MAC addresses are detected.

Syntax

set newaddrtrap [port-string] {enable | disable}

Parameters

Defaults

If port‐string is not specified, the trap function is set globally.

Mode

Switch mode, read‐write.

Usage

This command enables and disables sending SNMP trap messages when a new source MAC 
address is detected by a port. If the port is a CDP port, however, traps for new source MAC 
addresses will not be sent.

The default mode is disabled globally and per port.

Example=

This example enables the trap function globally and then on Gigabit Ethernet ports 1 through 5 in 
slot 1.

D2(rw)->set newaddrtrap enable
D2(rw)->set newaddrtrap ge.1.1-5 enable

show snmp notify

Use this command to display the SNMP notify configuration, which determines the management 
targets that will receive SNMP notifications.

Syntax

show snmp notify [notify] [volatile | nonvolatile | read-only]

Parameters

port‐string

(Optional) Enable or disable the new MAC addresses trap function on 
specific ports. 

enable | disable

Enable or disable the new MAC addresses trap function. If entered 
without the port‐string parameter, enables or disables the function 
globally. When entered with the port‐string parameter, enables or 
disables the function on specific ports.

notify

(Optional) Displays notify entries for a specific notify name.

volatile | 
nonvolatile | read‐
only

(Optional) Displays notify entries for a specific storage type.

This manual is related to the following products: