Show logging application, Show logging application -6 – Enterasys Networks Enterasys D2 D2G124-12P User Manual
Page 344
show logging application
12-6 Logging and Network Management
Defaults
At least one optional parameter must be entered.
All three optional keywords must be entered to reset all logging values to defaults.
Mode
Switch command, read‐write.
Example
This example shows how to reset the Syslog default severity level to 6:
D2(su)->clear logging default severity
show logging application
Use this command to display the severity level of Syslog messages for one or all applications
configured for logging on your system.
Syntax
show logging application [mnemonic | all]
Parameters
Defaults
If no parameter is specified, information for all applications will be displayed.
Mode
Switch command, read‐only.
port
(Optional) Resets the default UDP port the client uses to send to the server
to 514.
mnemonic
(Optional) Displays severity level for one application configured for
logging. Mnemonics will vary depending on the number and types of
applications running on your system. Sample mnemonics and their
corresponding applications are listed in
Note: Mnemonic values are case sensitive and must be typed as they appear in
all
(Optional) Displays severity level for all applications configured for
logging.