Chapter 30

Using a 9/Series Dual--Processing System

30-5

You can use QuickCheck as a program “syntax only” checker

(no graphics) in both processes at the same time.

Error Messages

The control displays error messages on the screen for only the currently

active process (except on split-screens). The name of the currently active

process flashes in reverse video if an error occurs in another process.

Change to the appropriate process to display the current errors for that

process.

On a split-screen display, the control displays the full error messages for

both processes, regardless of which process is currently active.

The control keeps separate error message logs for each process. The error

logs list the errors in sequential order.

Refer to page NO TAG for more details on error messages.

Single-Digit Feedrates

Both processes share one table of single-digit feedrates. The control looks

to the single-digit feedrate table when it encounters a single-digit F-word

during block execution. The feedrate in this table that corresponds to the

single digit becomes the active feedrate. You cannot define different

single-digit feedrate tables for each process.

The rapids for each individual--axis determine the feedrate used for F0.

Your system installer determines the rapid for each axes.

Refer to page 3-23 for information on single-digit feedrates.