Running a Program

Chapter 7

7-27

To perform a program restore operation after automatic program execution

has been interrupted follow these steps:

1.

Press the

{PRGRAM MANAGE}

softkey.

(softkey level 1)

PRGRAM

MANAGE

OFFSET MACRO

PARAM

QUICK

CHECK

SYSTEM

SUPORT

FRONT

PANEL

ERROR

MESAGE

PASS-

WORD

SWITCH

LANG

Important: DO NOT SELECT A PROGRAM AS AN ACTIVE

PROGRAM. Do not disable the currently active program (if any). If a

program is reselected as active or disabled by the operator the program

restore feature is canceled.

2.

Press the

{RESTRT PRGRAM}

softkey. The control automatically

re-selects the interrupted program if it was disabled by the control

when power was lost.

REFORM

MEMORY

ACTIVE

PRGRAM

EDIT

PRGRAM

RESTRT

PRGRAM

DISPLY

PRGRAM

COPY

PRGRAM

VERFY

PRGRAM

PRGRAM

COMENT

DELETE

PRGRAM

RENAME

PRGRAM

INPUT

DEVICE

(softkey level 2)

3.

To automatically search for the block in the current program that was

interrupted press the

{EXEC}

softkey.

The control will locate an @ symbol to the left of the block

immediately before the block that automatic execution was

interrupted at.

If this is not the block to begin execution from, press the

{QUIT}