6 adc status register – Rainbow Electronics AT91CAP9S250A User Manual
Page 954

954
6264A–CAP–21-May-07
AT91CAP9S500A/AT91CAP9S250A
46.6.6
ADC Status Register
Register Name:
ADC_SR
Access Type:
Read-only
• EOCx: End of Conversion x
0 = Corresponding analog channel is disabled, or the conversion is not finished.
1 = Corresponding analog channel is enabled and conversion is complete.
• OVREx: Overrun Error x
0 = No overrun error on the corresponding channel since the last read of ADC_SR.
1 = There has been an overrun error on the corresponding channel since the last read of ADC_SR.
• DRDY: Data Ready
0 = No data has been converted since the last read of ADC_LCDR.
1 = At least one data has been converted and is available in ADC_LCDR.
• GOVRE: General Overrun Error
0 = No General Overrun Error occurred since the last read of ADC_SR.
1 = At least one General Overrun Error has occurred since the last read of ADC_SR.
• ENDRX: End of RX Buffer
0 = The Receive Counter Register has not reached 0 since the last write in ADC_RCR or ADC_RNCR.
1 = The Receive Counter Register has reached 0 since the last write in ADC_RCR or ADC_RNCR.
• RXBUFF: RX Buffer Full
0 = ADC_RCR or ADC_RNCR have a value other than 0.
1 = Both ADC_RCR and ADC_RNCR have a value of 0.
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
RXBUFF
ENDRX
GOVRE
DRDY
15
14
13
12
11
10
9
8
OVRE7
OVRE6
OVRE5
OVRE4
OVRE3
OVRE2
OVRE1
OVRE0
7
6
5
4
3
2
1
0
EOC7
EOC6
EOC5
EOC4
EOC3
EOC2
EOC1
EOC0