7 test modes – Rainbow Electronics AT91CAP9S250A User Manual
Page 557

557
6264A–CAP–21-May-07
AT91CAP9S500A/AT91CAP9S250A
35.6.7
Test Modes
The USART can be programmed to operate in three different test modes. The internal loopback
capability allows on-board diagnostics. In the loopback mode the USART interface pins are dis-
connected or not and reconfigured for loopback internally or externally.
35.6.7.1
Normal Mode
Normal mode connects the RXD pin on the receiver input and the transmitter output on the TXD
pin.
Figure 35-38. Normal Mode Configuration
35.6.7.2
Automatic Echo Mode
Automatic echo mode allows bit-by-bit retransmission. When a bit is received on the RXD pin, it
is sent to the TXD pin, as shown in
. Programming the transmitter has no effect on
the TXD pin. The RXD pin is still connected to the receiver input, thus the receiver remains
active.
Figure 35-39. Automatic Echo Mode Configuration
35.6.7.3
Local Loopback Mode
Local loopback mode connects the output of the transmitter directly to the input of the receiver,
as shown in
. The TXD and RXD pins are not used. The RXD pin has no effect on
the receiver and the TXD pin is continuously driven high, as in idle state.
Figure 35-40. Local Loopback Mode Configuration
Receiver
Transmitter
RXD
TXD
Receiver
Transmitter
RXD
TXD
Receiver
Transmitter
RXD
TXD