Rainbow Electronics AT91CAP9S250A User Manual
Page 837

837
6264A–CAP–21-May-07
AT91CAP9S500A/AT91CAP9S250A
42.5.26.15
Receive Symbol Errors Register
Register Name:
EMAC_RSE
Access Type:
Read/Write
• RSE: Receive Symbol Errors
An 8-bit register counting the number of frames that had
rx_er
asserted during reception. Receive symbol errors are also
counted as an FCS or alignment error if the frame is between 64 and 1518 bytes in length (1536 if bit 8 is set in the network
configuration register). If the frame is larger, it is recorded as a jabber error.
42.5.26.16
Excessive Length Errors Register
Register Name:
EMAC_ELE
Access Type:
Read/Write
• EXL: Excessive Length Errors
An 8-bit register counting the number of frames received exceeding 1518 bytes (1536 if bit 8 set in network configuration
register) in length but do not have either a CRC error, an alignment error nor a receive symbol error.
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
–
–
–
–
–
–
7
6
5
4
3
2
1
0
RSE
31
30
29
28
27
26
25
24
–
–
–
–
–
–
–
–
23
22
21
20
19
18
17
16
–
–
–
–
–
–
–
–
15
14
13
12
11
10
9
8
–
–
–
–
–
–
–
–
7
6
5
4
3
2
1
0
EXL