12 phy maintenance register – Rainbow Electronics AT91CAP9S250A User Manual
Page 821

821
6264A–CAP–21-May-07
AT91CAP9S500A/AT91CAP9S250A
42.5.12
PHY Maintenance Register
Register Name:
EMAC_MAN
Access Type:
Read/Write
• DATA
For a write operation this is written with the data to be written to the PHY.
After a read operation this contains the data read from the PHY.
• CODE:
Must be written to 10. Reads as written.
• REGA: Register Address
Specifies the register in the PHY to access.
• PHYA: PHY Address
• RW: Read/Write
10 is read; 01 is write. Any other value is an invalid PHY management frame
• SOF: Start of frame
Must be written 01 for a valid frame.
31
30
29
28
27
26
25
24
SOF
RW
PHYA
23
22
21
20
19
18
17
16
PHYA
REGA
CODE
15
14
13
12
11
10
9
8
DATA
7
6
5
4
3
2
1
0
DATA
See also other documents in the category Rainbow Electronics Sensors:
- MAX5151 (16 pages)
- MAXQ3108 (64 pages)
- MAX5661 (39 pages)
- MAX6691 (7 pages)
- MAX5362 (12 pages)
- ADC10158 (26 pages)
- MAX8922L (14 pages)
- MAX8596Z (8 pages)
- MAX7491 (18 pages)
- MAX15040 (15 pages)
- MAX5177 (16 pages)
- ADC08138 (22 pages)
- MAX5961 (42 pages)
- T89C51RD2 (86 pages)
- MAX16055 (9 pages)
- MAX6659 (17 pages)
- ADC0820 (20 pages)
- MAX6678 (19 pages)
- MAX8884Z (15 pages)
- MAX16915 (9 pages)
- MAX8620 (18 pages)
- MAX5144 (12 pages)
- MAX6670 (8 pages)
- MAX8760 (39 pages)
- W78C32C (14 pages)
- MX7533 (8 pages)
- MAX8727 (13 pages)
- MAX9053 (15 pages)
- W78C54 (16 pages)
- MAX8614B (15 pages)
- W90N740 (219 pages)
- MAX6626 (13 pages)
- ADC10738 (30 pages)
- MAX17000 (31 pages)
- MAX5051 (21 pages)
- MAXQ1004 (18 pages)
- MAX6871 (51 pages)
- MX7847 (12 pages)
- MAX6608 (6 pages)
- MAX17083 (15 pages)
- MAX6641 (17 pages)
- MAX5251 (16 pages)
- MAX6338 (8 pages)
- MAX6690 (16 pages)
- MAX8668 (18 pages)