SCSI SCRIPTS Instruction Set
Version 2.2
Copyright © 2000–2003 by LSI Logic Corporation. All rights reserved.
011
XOR data with register and
place the result in the same
register. Syntax: “Move
RegA XOR data8 to RegA”
XOR data with register and
place the result in the
register. Syntax: “Move
RegA XOR data8 to SFBR”
XOR data with SFBR and
place the result in the
register. Syntax: “Move
SFBR XOR data8 to RegA”
100
AND data with register and
place the result in the same
register. Syntax: “Move
RegA & data8 to RegA”
AND data with register and
place the result in the
register. Syntax: “Move
RegA & data8 to SFBR”
AND data with SFBR and
place the result in the
register. Syntax: “Move
SFBR & data8 to RegA”
101
2
Shift register one bit to the
right and place the result in
the same register. Syntax:
“Move RegA SHR RegA”
Shift register one bit to the
right and place the result in
the
register.
Syntax: “Move RegA SHR
SFBR”
Shift the SFBR register one
bit to the right and place the
result in the register. Syntax:
“Move SFBR SHR RegA”
110
Add data to register without
carry and place the result
in the same register.
Syntax: “Move RegA +
data8 to RegA”
Add data to register without
carry and place the result in
the
register.
Syntax: “Move RegA + data8
to SFBR”
Add data to SFBR without
carry and place the result in
the register. Syntax: “Move
SFBR + data8 to RegA”
111
Add data to register with
carry and place the result
in the same register.
Syntax: “Move RegA +
data8 to RegA with carry”
Add data to register with
carry and place the result in
the
register.
Syntax: “Move RegA + data8
to SFBR with carry”
Add data to SFBR with carry
and place the result in the
register. Syntax: “Move
SFBR + data8 to RegA with
carry”
1. Substitute the desired register name or address for “RegA” in the syntax examples. data8 indicates
eight bits of data. Use SFBR instead of data8 to add two register values.
2. Data is shifted through the Carry bit and the Carry bit is shifted into the data byte.
Table 5.1
Read/Write Instructions
1
(Cont.)
Operator
Opcode 111
Read Modify Write
Opcode 110
Move to SFBR
Opcode 101
Move from SFBR