Dell PowerEdge VRTX User Manual
Page 319

319
FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Dell Plasma\User
Guide\Plasma_UGSwitching_VLAN.fm
D E L L CO N F I D E N T I A L – P R E L I MI N A RY 4/ 1 8 /1 3 - F O R PR O O F O N LY
• Admit Untagged Only — Only untagged packets are accepted on
the port.
–
Ingress Filtering — Enable/disable ingress filtering, which discards
packets that are destined to VLANs of which the specific port is not a
member.
–
Native VLAN ID(1-4094) — Enter VLAN used for untagged traffic to
trunk ports.
–
Multicast VLAN ID(1-4094) — Enter VLAN used for Multicast TV
VLAN traffic on access ports.
–
Customer VLAN ID(1-4094) — Enter VLAN used for customer
ports.
Assigning Ports to VLAN Groups Using CLI Commands
The following table summarizes the CLI commands for assigning ports to
VLAN groups.
Table 12-2. Port-to-VLAN Group Assignments CLI Commands
CLI Command
Description
switchport general acceptable-
frame-type {tagged-only|untagged-
only|all}
no switchport general acceptable-
frame-type
Configures ingress filtering based
on packet type tagged/untagged.
Use the no form of this command
to return to default.
switchport mode
{access|trunk|general|private-vlan
{promiscuous |host}|customer}
no switchport mode
Configures the VLAN
membership mode of a port.
Use the no form of this command
to restore the default
configuration.
switchport access vlan {vlan-id |
none}
no switchport access vlan
Configures the VLAN ID when
the interface is in access mode.
Use the no form of this command
to restore the default
configuration.
switchport trunk allowed vlan {all
|none|add vlan-list|remove vlan-
list|except vlan-list}
Sets the trunk characteristics
when the interface is in Trunking
mode.