For a device to be authenticated and authorized at a DVA-enabled port:
• The RADIUS server must authenticate the device and dynamically assign
a VLAN to the device.
• The assigned VLAN must not be the default VLAN and must have been
created on the switch.
• The switch must not be configured to use both a DVA and a MAC-based
VLAN group.
• A RADIUS server must support DVA with RADIUS attributes tunnel-type
(64) = VLAN (13), tunnel-media-type (65) = 802 (6), and tunnel-private-
group-id = a VLAN ID.
Dynamic Policy/ACL Assignment
The Dynamic Policy/ACL Assignment feature enables specifying a user-
defined ACL or policy in the RADIUS server. After a successful
authentication, the user is assigned that ACL.
Authentication Methods
The possible authentication methods are:
• Dot1x — The switch supports this authentication mechanism, as
described in the standard, to authenticate and authorize Dot1x
supplicants.
•
MAC-based — The switch can be configured to use this method to
authenticate and authorize devices that do not support Dot1x. The switch
emulates the supplicant role on behalf of the non-Dot1x-capable devices,
and uses the MAC address of the devices as the username and password,
when communicating with the RADIUS servers. MAC addresses for
username and password must be entered in lower case and with no
delimiting characters (for example: aaccbb55ccff). To use MAC-based
authentication at a port:
–
A Guest VLAN must be defined.
–
The port must be Guest-VLAN-enabled.
–
The packets from the first supplicant, at the port before it is
authorized, must be untagged.