beautypg.com

Back pressure, Port default settings, Jumbo frames – Dell PowerEdge VRTX User Manual

Page 251

background image

251

FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\Dell Plasma\User

Guide\Plasma_UGSwitching_Ports.fm

D E L L CO N F I D E N T I A L – P R E L I MI N A RY 4/ 1 8 /1 3 - F O R PR O O F O N LY

Flow control on the device works in Receive-Only mode, meaning that the

interfaces with enabled flow control receive PAUSE frames, but do not send

them.
When flow control is enabled, the system buffers are allocated per port so

that if the buffers of one port are consumed, other ports will still have their

free buffers.

Back Pressure

The device supports back pressure for ports configured to Half Duplex mode.

By default, this feature is disabled, and it can be enabled per port. The

back-pressure mechanism prevents the sender from transmitting additional

traffic temporarily. The receiver may occupy a link so it becomes unavailable

for additional traffic.

Port Default Settings

Table 8-1 describes the port default settings.

Jumbo Frames

Jumbo frames are frames of up to 10 Kb in size. If Jumbo frames are not

enabled, the system supports a packet size of up to 1,632 bytes.
To enable jumbo frames:

1 Click Switching > Ports > Jumbo Frames in the tree view to display the

Jumbo Frames page.
The current jumbo frames setting is displayed

Table 8-1. Port Default Settings

Function

Default Setting

Port speed and mode

10/100/1000 BaseT copper: auto-negotiation
SFP+1000/10G Mbps full duplex, auto discovery

Port forwarding state

Enabled

Port tagging

No tagging

Flow Control

On

Back Pressure

Off