Chapter 19
Comparison Instructions

19–9

SLC 5/02 Processors Only

Limit Test

LIM

Input Instruction

LIM

LIM

LIMIT TEST
Low Lim

N7:0

14

Test

50

High Lim

N7:1

70

F1

F2

F3

F4

F5

ZOOM on LIM –|LIM|– 2.3.0.0.1
NAME: LIMIT TEST
LOW LIM: N7:0 14
TEST: 50 50
HIGH LIM: N7:1 70

EDT_DAT

HHT Ladder Display:

HHT Zoom Display:

Ladder Diagrams and APS Displays:

(online monitor mode)

This input instruction tests for values within or outside a specified range,
depending on how you set the limits.

Entering Parameters

Low Limit, Test, and High Limit values you program can be word addresses
or decimal values, restricted to the following combinations:

If the Test parameter is a program constant, both the Low Limit and High
Limit parameters must be word addresses.

If the Test parameter is a word address, the Low Limit and High Limit
parameters can be be either a program constant or a word address.

Limit Test (LIM)