beautypg.com

Rockwell Automation 1747-PT1, D1747NP002 Hand-Held Terminal User Manual

Page 118

background image

Chapter 7
Creating and Editing a Program File

7–6

Entering an Examine if Closed Instruction

1. Press

[F1]

, INS_INST. The following display appears:

F1

F2

F3

F4

F5

2.0.0.0.*

BIT

TMR/CNT

I/O_MSG

CPT/MTH

OFL

>

COMPARE

<

END

>

I

I

2. Press

[F1]

, BIT. The following display appears:

F1

F2

F3

F4

F5

2.0.0.0.*

>

] [

( )

]/[

( )

L

OFL

( )

U

<

END

>

I

I

3. Press

[F1]

, —] [— , for the examine if closed instruction.

The following zoom display appears:

ENTER BIT ADDR:

ZOOM on XIC
NAME:

EXAMINE IF CLOSED

BIT ADDR:

F1

F2

F3

F4

F5

] [

2.0.0.0.*

This symbol indicates that the
HHT has automatically
shifted for you. You can then
enter the file type ( I, O, S, B,
T, C, R, and N).

4. At the

ENTER BIT ADDR:

prompt, type the address

I:1/0

, which is an

abbreviated form of the address. The display appears as follows:

ENTER BIT ADDR:I:1/0

ZOOM on XIC
NAME:

EXAMINE IF CLOSED

BIT ADDR:

F1

F2

F3

F4

F5

] [

2.0.0.0.*

5. Before continuing, make certain that the information entered is correct. If

you entered the wrong instruction by mistake, press

[ESC]

twice and

re–enter the correct instruction. If you entered the wrong address, press

[ESC]

once and re–enter the correct address. When all the information

displayed is correct, press

[ENTER]

.