background image

Chapter 10
Downloading/Uploading a Program

10–5

4. Press

[F3]

, ATTACH. If a password is required for program 03CLOCK,

the following display appears:

Program Directory

Programmer Processor

Prog:

1000

Prog:

03CLOCK

File:

222

File:

03M

Exec Files:

4

Exec Files:

3

Data Files:

9

Data Files:

9

ENTER PASSWORD:

PRG

F1

F2

F3

F4

F5

or this display appears after the password is entered (for the current online
program, which is 03CLOCK) or if a password is not required:

Program Directory

Programmer Processor

F1

F2

F3

F4

F5

CLR_PRC

DWNLOAD

OFFLINE

MODE

UPLOAD

Prog:

1000

Prog:

03CLOCK

File:

222

File:

03M

Exec Files:

4

Exec Files:

3

Data Files:

9

Data Files:

9

PROGRAM FILES DIFFER

PRG

5. Press

[F2]

, UPLOAD. The display changes as follows:

Program Directory

Programmer Processor

F1

F2

F3

F4

F5

NO

YES

Prog:

1000

Prog:

03CLOCK

File:

222

File:

03M

Exec Files:

4

Exec Files:

3

Data Files:

9

Data Files:

9

OVERWRITE EXISTING PROGRAM?

PRG

6. Press

[F2]

, YES to replace program 1000 with 03CLOCK in the HHT

RAM.

Program 03CLOCK is now stored in the HHT RAM and program 1000
has been erased.

You are now ready to perform the following functions:

go offline and edit the program

change processor operating mode

clear processor memory

change the password/master password

transfer memory

monitor or edit data files