background image

Chapter 19
Comparison Instructions

19–4

Less Than

LES

Input Instruction

LES

LES

LESS THAN
Source A

N7:1

0

Source B

612

F1

F2

F3

F4

F5

ZOOM on LES –|LES|– 2.3.0.0.1
NAME: LESS THAN
SOURCE A: N7:1 0
SOURCE B: 612 612

EDT_DAT

HHT Ladder Display:

HHT Zoom Display:

Ladder Diagrams and APS Displays:

(online monitor mode)

When the value at source A is less than the value at source B, this instruction
is logically true. If the value at source A is greater than or equal to the value
at source B, this instruction is logically false.

Entering Parameters

You must enter a word address for source A. You can enter a program
constant or a word address for source B. Signed integers are stored in two’s
complementary form.

Less Than (LES)