Chapter 7
Creating and Editing a Program File

7–17

4. Press

[F3]

, MOD_INST, then

[ZOOM]

.

The following display appears with the cursor on the first character of the
instruction address, on the prompt line:

ZOOM on XIC
NAME:

EXAMINE IF CLOSED

BIT ADDR:I1:1.0/2

ENTER BIT ADDR: I1:1.0/2

F1

F2

F3

F4

F5

] [

2.0.0.0.2

ACCEPT

EDT_DAT

5. To change the address:

either write over the

2

with a

1

by pressing the

[

]

key seven times

to position the cursor over the

2

, then press

[1]

, then

[ENTER]

or enter the entire new address and then press

[ENTER]

Important: When using the second method, you must press the

[SHIFT]

key for the file type (I, O, B...). Also, if the previous address
contains more characters than the new one, you must use the

[SPACE]

and the

[

]

keys to clear each remaining character

before pressing

[ENTER]

.

When the new address is displayed on the prompt line:

ZOOM on XIC
NAME:

EXAMINE IF CLOSED

BIT ADDR: I1:1.0/1

ENTER BIT ADDR: I1:1.0/1

F1

F2

F3

F4

F5

] [

2.0.0.0.2

ACCEPT

EDT_DAT

6. Press

[F5]

, ACCEPT. The display returns to the ladder display, and the

address is changed, as indicated in the upper left corner.

I

I

] [

2.0.0.0.2

OFL

] [

( )

] [

] [

( )

<

END

>

XIC:I1:1.0/1

NO FORCE

F1

F2

F3

F4

F5

BIT

TMR/CNT

I/O_MSG COMPARE

CPT/MTH

7. To accept the new address, press

[ESC]

once to display the proper menu,

then press

[F5]

, ACP_RNG.

8. Save the changes.