C00712 | la_tabpos: phi connection list, C00712, 15 parameter reference – Lenze 8400 HighLine User Manual
Page 958
15
Parameter reference
15.2
Parameter list | C00712
958
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00712
C00711/43
0: Not connected
: bMckOperationMode_4
Control input for MCK operating mode changeover value
4
C00711/44
0: Not connected
: bMckOperationMode_8
Control input for MCK operating mode changeover value
8
C00711/45
0: Not connected
: bPosProfileNo_1
Control input for selection of profile number value 1
C00711/46
0: Not connected
: bPosProfileNo_2
Control input for selection of profile number value 2
C00711/47
0: Not connected
: bPosProfileNo_4
Control input for selection of profile number value 4
C00711/48
0: Not connected
: bPosProfileNo_8
Control input for selection of profile number value 8
C00711/49
0: Not connected
: bFreeIn1
Input for binary user signal 1
C00711/50
0: Not connected
: bFreeIn2
Input for binary user signal 2
C00711/51
0: Not connected
: bFreeIn3
Input for binary user signal 3
C00711/52
0: Not connected
: bFreeIn4
Input for binary user signal 4
C00711/53
0: Not connected
: bFreeIn5
Input for binary user signal 5
C00711/54
0: Not connected
: bFreeIn6
Input for binary user signal 6
C00711/55
0: Not connected
: bFreeIn7
Input for binary user signal 7
C00711/56
0: Not connected
: bFreeIn8
Input for binary user signal 8
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00711 | LA_TabPos: Digital connection list
Data type: UNSIGNED_16
Index: 23864
d
= 5D38
h
Parameter | Name:
C00712 | LA_TabPos: phi connection list
Data type: UNSIGNED_16
Index: 23863
d
= 5D37
h
Connection parameters for "Table positioning" application: 32-bit inputs
• Selection of the 32-bit output signals for connection with the 32-bit input signals
• The selection list contains all 32-bit output signals which can be assigned to the 32-bit inputs mapped by the
subcodes.
Selection list
See
selection list - angle signals
Subcodes
Lenze setting
Info
C00712/1
0: Not connected
: dnPosProfilePosition
Input for selecting the target position in [increments]
C00712/2
0: Not connected
: dnFreeIn1
Input for 32-bit user signal 1
C00712/3
0: Not connected
: dnFreeIn2
Input for 32-bit user signal 2
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1