C00355
C00356
Parameter | Name:
C00355 | Active COBID
Data type: UNSIGNED_16
Index: 24220
d
= 5E9C
h
Display of the COBID of the PDOs that is active in the CAN stack
System bus "CAN on board": Identifier of the process data objects
Display range
(min. value | unit | max. value)
0
2047
Subcodes
Info
C00355/1
Active COBID CAN1_IN
C00355/2
Active COBID CAN1_OUT
C00355/3
Active COBID CAN2_IN
C00355/4
Active COBID CAN2_OUT
C00355/5
Active COBID CAN3_IN
C00355/6
Active COBID CAN3_OUT
C00355/7
Active COBID CAN4_IN
•
From version 15.00.00
C00355/8
Active COBID CAN4_OUT
•
From version 15.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C00356 | CAN time settings
Data type: UNSIGNED_16
Index: 24219
d
= 5E9B
h
Different time settings for the CAN interface
Setting range
(min. value | unit | max. value)
0
ms
65000
Subcodes
Lenze setting
Info
C00356/1
3000 ms
CAN delay boot-up - operat.
• Delay time for NMT state change from "Boot-up" to
"Operational".
C00356/2
0 ms
CAN2_OUT cycle time
C00356/3
0 ms
CAN3_OUT cycle time
C00356/4
0 ms
CANx_OUT operat. - 1.transmit
• When the "Operational" NMT status is reached, the
delay time set here is started. After the delay time has
been elapsed, the PDOs CAN2_OUT and CAN3_OUT
are sent for the first time.
C00356/5
0 ms
CAN1_OUT cycle time
C00356/6
0 ms
CAN4_OUT cycle time
•
From version 15.00.00
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1