Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
533
8
Basic drive functions (MCK)
8.4
Basic settings
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Re-activation after acknowledging the error
When the error has been acknowledged and the limit switch is still active, the following action is
required for a renewed activation of the monitoring depending on the operating mode:
Operating mode
Action for (re) activation
Limit switch is activated and setpoint in direction of the activated limit switch is pending
Note: If the setpoint e.g. is specified via an analog potentiometer, potentiometer noise can
mean an unintentional setpoint causing the error to be set again.
Limit switch is activated and bHomStartStop = TRUE
Limit switch is activated and manual jog in direction of the activated limit switch
Limit switch is activated and setpoint command has been transmitted
Setting of the operating mode
Limit switch is activated and setpoint in direction of the activated limit switch is pending