C01150 | l_phaseintk: function, C01151 | l_phaseintk: compare, C01201 | mck: cycle – Lenze 8400 HighLine User Manual
Page 1062: C01201/1, Hen the cycle, C1201/1, Is set to, 15 parameter reference

15
Parameter reference
15.2
Parameter list | C01150
1062
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01150
C01151
C01201
Parameter | Name:
C01150 | L_PhaseIntK: Function
Data type: UNSIGNED_8
Index: 23425
d
= 5B81
h
Loading behaviour of the integrator
Selection list
Info
0 Loading with level
Load integrator with TRUE level at the input bLoad
1 Loading with edge
Load integrator with FALSE/TRUE edge at the input
bLoad
2 Loading with level + reset
Load integrator when the comparison value (
) is
reached or with TRUE level at the bLoad input
Subcodes
Lenze setting
Info
C01150/1
0: Loading with level
: Function
C01150/2
0: Loading with level
: Function
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01151 | L_PhaseIntK: Compare
Data type: INTEGER_32
Index: 23424
d
= 5B80
h
Comparison value
Setting range
(min. value | unit | max. value)
0
2147418112
Subcodes
Lenze setting
Info
C01151/1
0
: Comparison value
C01151/2
0
: Comparison value
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 1
Parameter | Name:
C01201 | MCK: Cycle
Data type: INTEGER_32
Index: 23374
d
= 5B4E
h
From version 06.00.00
Cycle for Modulo measuring system
• When the cycle is set to 0 units (Lenze setting), the traversing range is unlimited (classical measuring system).
Activation of the Modulo measuring system
Setting range
(min. value | unit | max. value)
0.0000
units
214748.3647
Subcodes
Lenze setting
Info
C01201/1
0.0000 units
MCK: Cycle
Read access Write access CINH PLC STOP No transfer COM MOT
Scaling factor: 10000