Use of l_curve_3 for tensile force characteristic, Use of the l_curve_3 for tensile, Force characteristic – Lenze 8400 HighLine User Manual
Page 1330: 17 function library
17
Function library
17.1
Function blocks
1330
Lenze · 8400 HighLine · Referenzhandbuch · DMS 10.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
17.1.69.1 Use of the L_Curve_3 for tensile force characteristic
In case of centre winders, the drive torque is transmitted from the centre via the individual layers
up to the winder surface. In case of smooth materials and high diameter areas, it is mostly required
to reduce the tensile force depending on the diameter.
The FB L_Curve_3 can be used to generate a tensile force profile depending on the diameter. For this
purpose, the selection "4: Out = f(characteristic)" has to be set in
.
The characteristic is marked by a starting area with constant evaluation (100 %) and a second area
in which the tensile force is adapted to the diameter.
The part of the characteristic that depends on the diameter can be generated for a linear tensile
force profile, a linear torque profile or based on a specified characteristic. The respective selection is
made in
Linear tensile force profile
• nD0_a serves to define at which diameter the tensile force decrease is to start.
(from V12.00.00)
Selection of the tensile force profile
Use of the L_Curve_3 for tensile
0 Linear tensile force profile
Lenze setting
1 Linear torque characteristic
2 Tensile force profile according to
characteristic
Parameter
Possible settings
Info
Characteristic for a linear tensile force profile (
Characteristic
Tensile force
Diameter
Function for D > D0:
D Current diameter (nDiameter_a)
D0 Starting point for diameter dependency (nD0_a)
HW Tensile force evaluation (nCurveCtrl_a)
DMin
(DMax)
100 %
D0
0 %
100 %
HW
100 %
nCurveCtrl_a = 50 %
100 %
D D0
–
100 % D0
–
-----------------------------
–
100 % HW
–
(
)
⋅